Input of the incident flux at the boundaries
Following text is valid both for input of the upper boundary condition
from the file RTEUBC.DAT and for the input of the lower
boundary condition from the file RTELBC.DAT.
IBCUP
0 - no incident radiation
1 - incident radiation is a blackbody
radiation of temperature TT and weakening
factor WEAK
2 - explicit input of the incident
flux
3 - explicit input of the incident flux
with a weakening factor WEAK
TT
temperature of the blackbody radiation
WEAK
weakening factor
1 line for each frequency point; lines must be in ascending frequency
order (this input is only for IBCUP>0).
If the input frequency points differ from the frequency points used
during calculation, then the flux is automatically interpolated.
I
no meaning, enables input of the output file
flux.lst (from the preceding runs of
this code)
FRBC(IJ)
frequency (in Hz)
X
no meaning, enables input of the output file
flux.lst (from the preceding runs of
this code)
FLBC(IJ)
flux
Last update 27.8.2001